站内搜索
|
详细信息 Product Name: Hc-C017 Hot Sale Automated Aed Automated External Defibrillator Model NO.: HC-C017 Charge Time: 8 Sec. to 150j; 10 Sec. to 200j (New Battery) Energy Sequence: 150, 150, 200j Trademark: Happycare Origin: China Product Description HC-C017 Hot sale Automated AED Automated External DefibrillatorFeatures for HC-C017 Hot sale Automated AED Automated External Defibrillator:HC-C017 AED Defibrillator (Automatic External Defibrillator) is a defibrillation device, which is safe, portable and easy to use. It can be applied in family and public place to give first aid for the sudden death symptom. Combined with advanced ECG analytical technique, the defibrillator can analyze the patients ECG, make a judgement for the patients cardiac condition and indicate whether the defibrillation is needed and the defibrillation strength. It can not only enhances the success rate of defibrillation, but also reduce the injury of defibrillation to heart to the utmost extent.There is low requirement for the operator to use the device. The defibrillator will guide the operator to carry out defibrillation treatment via voice prompt step by step, give safety alert if the occasion arises. It can carry out early defibrillation treatment effectively and protect the operator farthest, being very applicable to the emergency treatment for the sudden cardiac death patient in family and public place.Three-step defibrillation processTwo-button operationExtensive voice and visual prompts for the operatorBiphasic energy outputLock-out protection to prevent inadvertent defibrillationPC-based event review (optional)Multilingual selections are available. (optional)OutputBiphasic Truncated ExponentialEnergy Sequence150, 150, 200JCharge Time8 sec. to 150J; 10 sec. to 200J (New Battery)Analysis Time9 sec.The maximum time from the initiation of rhythm analysis toreadiness for discharge with a new batteryLess than 30 secondsThe maximum time from the initiation of rhythm analysis toreadiness for discharge after 6 shocksLess than 35 secondsThe maximum time from initially switching power on toreadiness for dischargeLess than 25 secondsAudible prompts22 audible promptsVisual promptsLED promptsControlsTwo buttons-ON/Off, ShockOutput Energy Accuracy±15% into any impedance from 25 to 175ΩThe Maximum Voltage1200±50VOutput disabled when the patient impedance is outside limits20Ωto 200ΩPhysicalDimensions303*216*89mmWeight2.0kgOperating Temperature0°C to 40°COperating HumidityRelative humidity between 30% and 95% (non-condensing)Storage Temperature (without battery)-20°C to 55°CStorage Humidity (without battery)Up to 95% (non-condensing)BatteryPart No.CR123A-4*2Non-rechargeable12V DC, 2.8AhCapacityAt 150 JoulesPictures for HC-C017 Hot sale Automated AED Automated External Defibrillator:
|